After plugging the inverter into the WiFi or installing the E-Net normally, you are unable to claim the device when using the app to create a plant.

  1. Check that the WiFi or E-Net indicator display is normal.

  2. Check the settings of the home router and confirm whether the “IP Address Assignment (DHCP)” function is ticked. If it is not checked, WiFi or E-Net cannot access the Internet, so, ticking is necessary.

After the app configures the WLAN, you return to other interfaces and are told that there is no available network.

Configuration WLAN, in order to normally use App’s monitoring function, it is necessary to disconnect the WLAN signal of App and inverter and connect the mobile phone to the home router network or data network.

E-Net indicator status description

indicator definition status description
RUN (blue):
run indicator, indicates the running status of the module
Normally On: the module is running normally
Off: the module is not running normally
COM (green):
communication indicator, indicates connection status of the router
Normally On: successfully connected to the home router
Blink: trying to connect to the home router
Off: configuration failed to connect to the home router
RUN (blue):
network light, indicates server connection status or upgrade
Normally On: successfully connected to data server
Flash: fast flash indicates upgrade is in progress; slow flash means communication with inverter is interrupted
Off: unable to connect to data server
NET (yellow):
network light, indicates the server connection status or upgrade
Normally On: successfully connected to the data server
Flash: upgrading the sub-device
Off: unable to connect to the data server
After completing the configuration of the home router, wait about 10 minutes for inverter E-Net to connect to the data server successfully, the NET indicator light is Normally On.

WLAN Indicator Status Description

indicator light definition status description
RUN (blue):
run indicator, indicates the running status of the module
Normally On: the module is running normally
Off: the module is not running normally
COM (green):
communication indicator, indicates that the router’s connection status
Normally On: successfully connected to the home router
Blink: trying to connect to the home router
Off: configuration failed to connect to the home router
NET (yellow):
network light, indicates server connection status or upgrade
Normally On: successfully connected to data server
Flash: indicates upgrade is in progress. Slow flash means that communication with inverter is interrupted
and goes out: unable to connect to data server
After the configuration of home router is completed, wait about 10 minutes for inverter WLAN to connect to data server successfully. Only when the NET indicator light is Normally On.

Eye indicator light status description (Eye V25, Eye V4, EyeS2, EyeM2)

LED type Description LED status status description
module running light
(RUN)
indicates whether the software and hardware of the module itself are operating normally Flashes once per second the current module is running normally
Flashes Irregularly, Normally On or Off abnormal operation of the current module
inverter communication lamp
(COM)
indicates whether the communication between the module and the inverter is normal Flash once per second normal communication with inverter
Flash Irregularly, Normally On or Off abnormal communication with inverter
networking indicator
(NET)
indicates the connection between the device and the background server Normally On connection to background server successful
Off communication with background server abnormal

Eye indicator status description (Eye V22, Eye V24)

LED type Description LED status status description
power indicator indicates whether the device is powered on normally Normally On the current device power supply is powered on normally
Off the current device is not powered
communication indicator indicates the RS485 serial communication status of the device Flashes fast (once for 0.5s, five times in a row) normal communication with inverter
Flashes slowly (once for 2s, five times in a row)Normal communication with the meter
OffNo data interaction
Networking indicator Indication of device networkingFlashConnected to the network
Normally OnData uploaded successfully
OffNo data interaction

Logger1000 Status of the LED Indicators

indicator (print) LED color LED status Description
Running indicator
(RUN)
Red/green Off No external power supply connected
Slow flash (Green) Normal running
Slow flash (Red) Device alarm
Steady on (Red) Logger1000 running fault
4G indicator*
(4G)
Blue Off No data communication
Steady on 4G connected successfully
Slow flash Data communication in process
WLAN indicator
(WLAN)
Blue Off No data communication
Steady on WiFi connected successfully
Slow flash Data communication in process

Note: * Only the Logger1000A is equipped with the 4G indicator.

EyeM4 Status of the LED Indicators

LED type Description LED status Status description
Running
(RUN)
Indicates whether the hardware and software of the module itself run normally Flash (Green) Normal operation
Flash (Red) Inverter fault
Off Module power-off
4G communication indicator
(4G)
Indicates the state of communication between the module and the base station On Connected with the based station
Off Not connected with the based station
Flash Data exchange in process
WiFi communication indicator
(WLAN)
Indicates the state of communication between the module and the router On Connected to the router
Off Not connected to the router
Flash Data exchange in process

WiNet-S Status of the LED Indicators

Indicator Status Description
Run Off Not connected to external power supply
Blinking green Normal operation
Steady red Module fault
WLAN Off No data exchange
On WiFi connected successfully
Blinking slowly In data exchange
Blinking quickly In smartConfig mode (factory default mode)
LAN Off No data exchange
Steady green Ethernet connected successfully
Steady green, blinking red In data exchange